End thermal resistance

The end thermal resistance element is made of specially processed wire and is attached to the front
  • Tel:0550-7591188
  • Fax:0550-7591188
  • Email:2136705934@qq.com
Description

The end thermal resistance element is made of specially processed wire and is attached to the front end of the thermometer. Compared with the general axial thermal resistance, the end thermal resistance can reflect the actual temperature of the measured end more accurately and quickly, and is suitable for measuring the end temperature of bearing bush or other parts.


● Main technical parameters


Temperature sensing element 0℃ resistance value (R100) and its resistance at 0℃ R0 classification number Cu50 :R0= 50±0.050 ω Cu100 :R0=100± 0.10 ω classification number Pt100:R0=100±0.12 ω (grade B) where :R0 is the component at 0℃ resistance value.


● Measuring range and tolerance (unit: mm)

The name of theTemperature range: ℃Allowable deviation △t℃Degree,
End copper resistor- 50-100Plus or minus (0.3 + 6.0 x 10-3 | t |)Or Cu100 Cu50 (G)
End platinum resistor- 150-200B: - (0.30 + 0.005 | t |)Pt100

specifications

Type no.

Degree,

Structural features

Temperature range: ℃

Protective tube material

Thermal response time

specifications

Nominal pressure

External wiring lead length L (mm)

Diameter D (mm)

M (mm)

WZCM-201

Cu50 Cu100

Fixed embedment or threaded connection- 50-100Copper T2 - YThe < 15Φ 6M8x0 .75Atmospheric pressure

500 
1000 
1500 
2000 
2500

WZPM-201Pt100- 150-200The < 15Φ 8.7M10x1
WZPM-201B

Note: WZPM-201B adopts the imported component WZPM-018, the accuracy grade is A.