YGC-F46R cable
- Tel:0550-7591188
- Fax:0550-7591188
- Email:2136705934@qq.com
Description
Ygc-f46r,ZR-F46-22 fluorine plastic insulated high temperature resistant power cable - Product characteristics and use
This product is fit for ac rated voltage up to and including 0.6/1 kv for fixed installation, power transmission and distribution line motor lead wire, high temperature resistance, corrosion resistance, resistance to acid and alkali and corrosive gas, waterproof and other characteristics, environment of high temperature electrical performance stability, large carrying capacity, long service life, widely used in metallurgy, electric power, petrochemical, large construction, automotive and other industries.
Two: product implementation standards
Q/HHTZH001.2
Flame retardant fire resistance test to comply with gb12666-90 standard
Three: use characteristics
1. Ac rated voltage: U0/U 0.6/1kV
2. Maximum operating temperature: polyperfluorinated ethylene propylene (F46) insulation does not exceed 200℃
Soluble polytetrafluoroethylene (PFA) insulation shall not exceed 260℃
3. Minimum ambient temperature: fluoroplastic insulation and sheath
-40℃ for fixed laying, -15℃ for non-fixed laying
4. The cable installation and laying temperature should not be lower than 0℃(fluorine plastic, silicone rubber and nitrile sheath cable should not be lower than -25℃).
5. The allowable bending radius of a single-core cable should be at least 15 times of the outer diameter of the cable
The multi-core cable should be at least 10 times of the cable diameter
Four: Basic model and name
Table 1
model | The product name | Normal operating temperature ℃ |
FF46 | Fluoroplastic insulated and sheathed power cable | - 60-200 |
FF46-22 | Fluorine plastic insulated and sheathed steel tape armored power cable | - 60-200 |
FF46P | Fluoroplastic insulated and jacketed copper braided shielded power cable | - 60-200 |
ZR-F46(FV) | Fluoroplastic insulated flame retardant PVC sheathed power cable | - 40-105 |
ZR-F46-22(FV22) | Fluorine plastic insulated steel tape armored flame retardant PVC sheathed power cable | - 40-105 |
ZR192-FF46 | PFA Insulated and sheathed power cable (imported raw material) | - 60-260 |
ZR192-FF46P | PFA insulated and jacketed copper braided shielded power cable (imported raw material) | - 60-260 |
ZR192-FF46-22 | PFA Insulated and sheathed steel tape armored power cable (imported raw material) | - 60-260 |
YGC-F46(FG) | Fluoroplastic insulated silicone rubber sheathed power cable | - 60-180 |
YGC-F46-22(FG22) | Fluorine plastic insulated steel tape armored silicone rubber sheathed power cable | - 60-180 |
YVF-F46 | Fluoroplastic insulated flame retardant nitrile PVC sheathed power cable | - 60-105 |
YVF-F46-22 | Fluorine plastic insulated steel tape armored flame retardant nitrile PVC sheathed power cable | - 60-105 |
Note: Add R to the original model of soft structure cable, copper wire in conductor core can be tinned.
Five: code name and meaning
Table 2.
Code name | Symbol meaning |
A series of codes | slightly |
F(F46) | Polyperfluoroethylene propylene (F46) |
YVF | Nitrile rubber |
G | Silicone rubber |
192 | Imported PFA insulation and sheath |
ZR(V) | Flame retardant polyvinyl chloride (flame retardant 70℃, 90℃, 105℃ three) |
22 | Steel tape armoured |
32 | Fine wire armour |
P | Braided copper shield |
R | Stranded conductor |
Six: main technical indicators
1. Refer to Table 1 of Appendix A for dc resistance of finished cable conductor (in accordance with GB3956).
The insulation resistance must be at least 500 ω /KM at 20 ° C and at least 10 ω /KM at 180 ° C
3. Finished cable withstands ac 50HZ3.5 kV /5min voltage test without breakdown.