0550-7591188|中文|English|Disclaimer|Sitemap

Advantages and uses of wire and cable flexibility

According to the model can be roughly divided into the following categories:


Flexible control cable


1. PVC outer sheathed flexible control drag chain cable, flame retardant CC101 Bending radius: 8X


2. PVC outer sheathed flexible shielded control drag chain cable, flame retardant CC111 Bending radius: 10X


3. PVC outer sheathed flexible control drag chain cable, flame retardant CC120 Bending radius: 5X


4. PVC outer sheath flexible shielding control drag chain cable, flame retardant CC121 bending radius: 8X


5, PUR outer sheath flexible control drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC127 Bending radius: 8X


6, PUR outer sheath flexible control shielding drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC117 Bending radius: 10X


7. Steel wire braided flexible control drag chain cable, anti-ultraviolet, low temperature, wear-resistant, CC158 bending radius: 10X


8, PETP outer sheath flexible control drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC160 Bending radius: 5X


9, PETP outer sheath flexible control shielding drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC133 bending radius: 10X


Flexible power cable


10. PVC outer sheathed flexible power drag chain cable, flame retardant CC305 Bending radius: 8X


11. PVC outer sheath shielded flexible power drag chain cable, flame retardant CC336 Bending radius: 10X


12, PETP outer sheath flexible shielding power drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC358 Bending radius: 10X


13, PETP outer sheath flexible shielding power drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC371 Bending radius: 8X


Flexible data/bus cables


14. PVC outer sheathed flexible shielded data drag chain cable. CC41 Bending Radius: 8X


15, PUR outer sheath flexible shielded data drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant **** Bending radius: 10X


16, PETP outer sheath flexible shielded data drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC46 Bending radius: 10X


17, PETP outer sheath flexible shielded data drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC48 Bending radius: 12X


Flexible Servo Cable


18, PUR outer sheath flexible shielded servo drag chain cable, oil resistance, hydrolysis resistance, UV resistance, low temperature resistance, wear resistance, flame retardant CC46 Bending radius: 10X


The flexible cable is different from the ordinary fixed installation cable. Please refer to the following installation and precautions during installation:


1. The laying of the drag chain cable cannot be twisted, that is, the cable cannot be unwound from one end of the cable reel or cable reel, but the cable should be unrolled by rotating the reel or cable reel first, and the cable can be unrolled or suspended if necessary. The cable used for this application can only be obtained directly from the cable reel


2. Pay attention to the small bending radius of the cable. (relevant information can be found in the selection table)


3. The cables must be laid loosely side by side in the drag chain, arranged as far as possible, separated by spacers or penetrated into the separation cavity of the neutral block of the bracket, the gap between the cables in the drag chain should be at least 10% of the cable diameter


4. The cables in the drag chain must not touch each other or be trapped together.


5. Both points of the cable must be fixed, or at least the moving end of the drag chain must be fixed. Generally, the distance between the moving point of the cable and the end of the drag chain should be 20-30 times the diameter of the cable.


6. Please ensure that the cable moves completely within the bending radius, i.e. no forced movement. The cables can thus be moved relative to each other or to the guide. After a period of operation, z.ui is good to check the position of the cable. This inspection shall be performed after the push-pull movement.


7. If the drag chain is broken, its cable also needs to be replaced, because the damage caused by excessive stretching cannot be avoided.


Advantages of flexible cables


Under the condition of meeting the same electrical requirements, the flexible cable has a smaller outer diameter and lighter weight than other similar cables. The bending performance of the flexible cable is very good, and the small bending radius of z.ui can reach 5 times the outer diameter of the cable.


Browse:
Return To The Top