3.6/6kV shielded flexible rubber sheathed cable (MT818.7-1999)

Purpose: This product is one of the series products of flexible rubber cable for mining, suitable for rated voltage level ground mobile mining machinery and equipment as power supply connection line

Service condition: the allowable operating temperature of the conductor is 90℃

Cable specification and name

model

The name of the

The main purpose

The MYP - 3.6/6

Mining mobile shield sleeve flexible cable

Rated voltage is 3.6/6kV mobile ground mine and mechanical power supply connection, the lower limit of ambient temperature is -20℃

3.6/6 MYPT -

Mining mobile metal shielded flexible cable

3.6/6 MYPD -

Mining mobile shield sleeve flexible cable

Rated voltage is 3.6/6kV mobile ground mine and mechanical power supply connection, the lower limit of ambient temperature is -40℃

3.6/6 MYPTD -

Mining mobile metal shielded flexible cable









Cable specifications and dimensions
 






Number of cores × nominal cross section of conductor (mm2)


Nominal thickness of sheath (mm)

Uyp-3.6/6, UYPD-3.6/6 cable Outer diameter (mm)

Power wire core insulation

Core power lines

Ground wire core

Nominal thickness (mm)

The minimum value

The maximum

3 x 16

1 x 16

4

5.5

51.3

57.3

3 x 25

1 x 16

4

5.5

53.9

59.9

3 x 35

1 x 16

4

5.5

57

63

3 x 50

1 x 25

4

5.5

60.8

66.8







Number of cores × nominal cross section of conductor (mm2)


Nominal thickness of sheath (mm)

Uyp-3.6/6, UYPD-3.6/6 cable Outer diameter (mm)

Power line core is absolutely

Core power lines

Ground wire core

Nominal edge thickness (mm)

The minimum value

The maximum

3 x 16

1 x 16/3

4

5.5

51.8

57.8

3 x 25

1 x 16/3

4

5.5

54.8

60.8

3 x 35

1 x 16/3

4

5.5

58.3

64.3

3 x 50

1 x 25/3

4

5.5

61.4

67.7


Technical performance
 



1. Insulation resistance value of power wire core of cable

Nominal cross section of power line core (mm2)

Minimum insulation resistance at 20℃ (M ω ·km)

16

750

25

650

35

550

50

500

2, insulation using ethylene-propylene rubber as the base material of insulation adhesive, tensile strength is not less than 6.5MPa.

3. Other electrical properties and mechanical properties of insulation and sheath of cable shall be regulated by GB3048 and GB2951.